The COMTEC® 6000 DustEx is the standard InSitu analyzer system for use in dust explosion zones 21/22
In accordance to the tough demands placed on measuring systems in high dust processes, the DustEx is ATEX*certified to II 2D Ex tD A21 IP6X T133°C/T141°C.
Being able to precisely determine the proportion of oxygen and COe in flue gas is the starting point for the safe and optimized operation of incinerators, as oxygen and COe are dependent to one another within a combustion process. Undesirable developments can thus be identified and rectified earlier, before any damage is caused.
The COMTEC® 6000 DustEx is also available for O2 only measurements.
*Please note ATEX certification is only recognised in Europe. Australia recognises IECEx. For IECEx, a third (certification) party is is required to make the design and manufacturing assessment to issues the IECEx certificate. In practice this means IECEx 02 requires more evidence and assurance from the manufacturer during the quality certification process. ATEX and IECEx both use the same standards (eg EN-IEC 60079-0), so they are technically almost identical.
Learn MoreInsertion depth of probes | 540 mm 960 mm |
O2 / COeranges | 0 – 25 % O2 0 to 1000 ppm COe (others on request) |
Sensor accuracy O2 | better 0,2% of measured value |
Sensor accuracy COe | better 5% of range end |
Reaction time | 0,5 s (process flow velocity > 10 m/sec.) |
Process gas temperature | max. 600 °C |
Ambient temperature | -20 °C to 55 °C (probe) -20 °C to 70 °C (electronic unit) |
Interface | HART, FIELDBUS, RS485, MODBUS RTU, RS232, ENOTEC REMOTE |
IP code | IP66 (probe) IP66 (electronic unit) |
Hi there, I'm Bronwyn. I've been with TES for 15 years and I'm the Category Manager for our Gasmet and CEMS equipment sales. My usual work days are Monday - Wednesday. If there's something I can help you with, please give me a call on 0404 161 353 or send me a message and myself or your local sales support will be in touch shortly!