HALO 3 CH4

The HALO 3 CH4 trace level methane gas analyzer provides users with the unmatched accuracy, reliability, speed of response and ease of operation that users of Tiger Optics analyzers have come to know and expect. Featuring Tiger Optics’ proven Cavity Ring-Down Spectroscopy-based trace gas sensor in a very compact and economic analyzer design, this versatile analyzer allows users to measure methane in most inert and passive gases with just one device. Users also enjoy freedom from requirements such as periodic sensor maintenance, span calibrations, purifier replacement and pump rebuilds. As a result, the HALO is ideally suited to many applications where trace gas measurement is extremely critical. These applications include silicon wafer manufacturing monitoring, fixed bulk gas continuous quality control, process tool monitoring, air separation, gas cylinder quality control and many other demanding applications.

Designed for trace level methane analysis, the HALO 3 CH4 offers:

  • Low single-digit parts per billion (ppb) methane detection capability in an array of gases
  • Absolute measurement (freedom from calibration gases)
  • Wide dynamic range
  • Low cost of ownership and operational simplicity
  • Clean technology—no external calibration gases required
  • Compact analyzer footprint.

Applications

  • Air Separation Units & Nitrogen Plants
  • Gas Quality Control
  • Gaseous CRMs & Calibration Gas Mixtures
  • High-Purity Gases & Systems
  • Research & Development.

Specifications

Brand

Laboratory & Scientific

Stack, Process & CEMS

Detection Capability

Detection and Matrix Range LDL (3σ) Precision (1σ) @ zero
CH4 in N2 0 – 8 ppm 1.6 ppb 0.6 ppb
CH4 in He 0 – 5 ppm 1.1 ppb 0.4 ppb
CH4 in Ar 0 – 7 ppm 1.4 ppb 0.5 ppb
CH4 in H2 0 – 8 ppm 1.6 ppb 0.6 ppb
CH4 in O2 0 – 6 ppm 1.1 ppb 0.4 ppb

Specifications

Performance
Operating range See Detection Capability table
Detection limit (LDL, 3σ/24h) See Detection Capability table
Precision (1σ, greater of) ± 0.75% or 1/3 of LDL
Accuracy (greater of) ± 4% or LDL
Speed of response < 1 minute to 95%
Environmental conditions 10°C to 40°C, 30% to 80% RH (non-condensing)
Storage temperature -10°C to 50°C
Gas Handling System and Conditions
Wetted materials 316 stainless steel (optional corrosion-resistant material), 10 Ra surface finish
Gas connections 1/4″ male VCR inlet and outlet
Leak tested to 1 x 10-9 mbar l / sec
Inlet pressure 30 − 125 psig (3.1 − 9.6 bara)
Flow rate Up to 1.8 slpm
Sample gases Most inert, toxic, passive and corrosive matrices
Gas temperature Up to 60°C
Dimensions, H x W x D
Standard sensor 8.73″ x 8.57″ x 23.6″ (222 mm x 218 mm x 599 mm)
Sensor rack (fits up to two sensors) 8.73″ x 19.0″ x 23.6″ (222 mm x 483 mm x 599 mm)
Weight
Standard sensor 28 lbs (12.7 kg)
Electrical
Alarm indicators 2 user programmable, 1 system fault, Form C relays
Power requirements 90 − 240 VAC, 50/60 Hz
Power consumption 40 Watts max.
Signal output Isolated 4−20 mA per sensor
User interfaces 5.7” LCD touchscreen, 10/100 Base-T Ethernet, RS-232
802.11g Wireless (optional), Modbus TCP (optional)
Certification CE Mark
Patents
U.S. Patent #7,277,177

Request information or pricing

If you need a quote, specifications or technical info, or anything else – please submit the form below and one of our team of experts will happily get back to you within 24 business hours. 

  • This field is for validation purposes and should be left unchanged.