Specifications
| Performance | |
| Measurement Principle | Broadband spectroscopy using 90° white-light scattering with Polychromatic LED |
| Particle size resolution | 256 sizes over 0.18 – 20µm range, combined to 64 channels for mass calculation |
| PM Mass Measurements | PM10, PM2.5 and PM10-2.5 simultaneously; PM1 (optional) |
| PM Mass Resolution Measurement Range | 0.1 – 10,000 µg/m3 |
| Mass Measurement & Display Resolution | 0.1 µg/m3 |
| Precision | ±0.5 ug/m3 (1-hr average) |
| Lower Detectable Limit | <0.1 ug/m3 (1-hr average) |
| Data Rate | 10s to 48hr (user selectable) |
| Mass Concentration Accuracy | Exceeds US EPA PM10 FEM and Class III FEM PM2.5 performance requirements for additive and multiplicative bias compared to FRM samplers |
| Flow Rate | 5.0-lpm sample flow (Standard model); 11.67-lpm optional bypass flow (with option 640x) |
| Flow Accuracy | Within ±1%; (Typically within ±0.5%) |
| Operating Conditions | |
| Operating Temperature | 0 – 50°C, non-condensing |
| Ambient Temperature | -40 – 60°C |
| Ambient Relative Humidity | 0 – 100% |
| Sample Humidity Control | 24VDC, 90W (max) heater controlled to 35% RH |
| Weatherproof enclosure required with 0 – 50°C, non-condensing environmental control | |
| Requires only 10-min warm-up time | |
| Interfaces and Data Storage | |
| T Series analyzer interface with full touch screen display and NumaView™ premium operating software and NumaView™ remote software | |
| 4Gb memory allows for > 1 year of internal data storage | |
| Front Panel USB Ports | 2x type-A Peripheral Ports |
| Ethernet Communication (supports TCP/IP Modbus and HTTP polling protocols) | |
| Electrical | |
| T640 instrument | 100 – 240VAC 50/60Hz, Power consumption < 120W @ 120VAC |
| External pump (for optional bypass flow – option 640x) | 100 – 120VAC 60Hz or 220-240VAC 50/60Hz, Power consumption <360W @ 120VAC |
| Physical Specifications | |
| Unit dimensions (HxWxD) | 7” x 17” x 14” (17.8 x 43.2 x 35.6 cm) |
| Unit weight | 19 lbs (8.6 kg) |
| Sample heater tube height | 43” (109 cm) |
| Sample heater tube weight | 6 lbs (2.7 kg) |
| Certifications | |
| US EPA PM2.5 Federal Equivalent Method EQPM-0516-236 | |
| US EPA PM2.5 Federal Equivalent Method EQPM-0516-238* | |
| US EPA PM10 Federal Equivalent Method EQPM-0516-239* | |
| US EPA PM10-2.5 Federal Equivalent Method EQPM-0516-240* | |
| *with 640x option
Specifications are subject to change without notice. |